The following audible (call progress) tones and power levels are used in North America (full definition see ANSI T1.401 Appendix D 1988)
| Name | Frequency (Hz) | Pattern |
| Dial tone | 350 + 440 | Steady on |
| Message Waiting | 350 + 440 | 10 bursts (0.1sec on, 0.1 sec off) then steady on |
| Recall dial tone/ Confirmation tone |
350 + 440 | 3 bursts (0.1 sec on, 0.1 sec off) then steady on |
| Line busy | 480 + 620 | 0.5 sec on, 0.5 sec off, repeating |
| Reorder | 480 + 620 | 0.25 sec on, 0.25 sec off, repeating |
| Audible Ringing | 440 + 480 | 2 sec on, 4 set off, repeating |
| Name | 350 Hz | 440 Hz | 480 Hz | 620 Hz |
| Dial tone Message Waiting Recall |
-29 to -10 dBm | -29 to -10 dBm | ||
| Line Busy Reorder |
-52 to -21 dBm | -52 to -21 dBm | ||
| Ringing | -47 to -16 dBm | -47 to -16 dBm |
Problems, comments, suggestions, corrections (including broken links) or something to add? Please take the time from a busy life to 'mail us' (at top of screen), the webmaster (below) or info-support at zytrax. You will have a warm inner glow for the rest of the day.
tech home
audio stuff
web stuff
dom stuff
css stuff
language stuff
regex stuff
rfc stuff
protocol stuff
cable stuff
lan wiring
rs232 wiring
howto stuff
survival stuff
wireless stuff
ascii codes
data rate stuff
telephony stuff
mechanical stuff
pc stuff
electronic stuff
tech links
open guides
RSS Feed
If you are happy it's OK - but your browser is giving a less than optimal experience on our site. You could, at no charge, upgrade to a W3C STANDARDS COMPLIANT browser such as Mozilla
ISO (International)
ANSI (US)
DIN (Germany)
ETSI (EU)
BSI (UK)
AFNOR (France)
TIA (US)
EIA (US)
ITU (International)
IEEE (US)
ETSI (EU)
OFTEL (UK)
|
Copyright © 1994 - 2010 ZyTrax, Inc. All rights reserved. Legal and Privacy |
site by zytrax![]() |
web-master at zytrax Page modified: February 07 2006. |